VIT-A

Series VIT-A distribution boards are equipped with an isolation transformer as well as with a changeover and monitoring module including all necessary monitoring components as to DIN VDE 100-7010 and IEC 60364-7-710 for IT systems:

  • Changeover device and voltage monitoring
  • Insulation monitoring
  • Load and temperature monitoring

The secondary side of the isolation transformer is equipped with at least 6 two-pole 
circuit breakers. Group 2 sockets are being connected to these.
In order to reduce or avoid noise disturbance by air circulating fans, waste heat is 
conducted by free convection.

¿Alguna duda? Contáctenos!

VIT-A
VIT-A

Series VIT-A distribution boards are equipped with an isolation transformer as well as with a changeover and monitoring module including all necessary monitoring components as to DIN VDE 100-7010 and IEC 60364-7-710 for IT systems:

  • Changeover device and voltage monitoring
  • Insulation monitoring
  • Load and temperature monitoring

The secondary side of the isolation transformer is equipped with at least 6 two-pole 
circuit breakers. Group 2 sockets are being connected to these.
In order to reduce or avoid noise disturbance by air circulating fans, waste heat is 
conducted by free convection.

¿Alguna duda? Contáctenos!

Características

  • Automatic changeover and monitoring device ATICS® including monitoring of i.e.:
    - Voltage monitoring of incoming supply
    - Output voltage monitoring
    - Correct operating times
    - Changeover times
    - Insulation resistance
    - Load current
    - Transformer temperature
    - At least 6 two-pole circuit breakers B16A
    - Isolation transformer (3150 VA – 8000VA)
  • Variable changeover time t ≤ 0.5…15 s
  • Exchange of information by means of bus technology
  • Connection facility for remote alarm indicator and operator panels CP9xx / CP305
  • Sheet steel housing as to DIN VDE 0100-710 (VDE 0100-710):2002-11, section 710.51.2.2
  • Designed in accordance with the requirements of applicable standards
  • Voluntary certification of changeover device by the independent German technical service, testing and inspection organization (TÜV)

Aplicaciones

  • Group 2 medical locations

VIT-A Variante(s)

TypePowerWeightLoss*
VIT-A-112S-5000 VAca. 145kgca. 200W
VIT-A-112S-6300 VAca. 150kgca. 210W
VIT-A-112S-8000 VAca. 160kgca. 230W
VIT-A-114S-5000 VAca. 155kgca. 200W
VIT-A-114S-6300 VAca. 160kgca. 210W
VIT-A-114S-8000 VAca. 170kgca. 230W

* Specification for energy efficient „Green Line“ Transformers.


Basic types

VIT-ANumber of circuitsDrawing No.Art No.
-112S-xxxx-69700071B101926**
-112S-xxxx-129700072B101927**
-114S-xxxx-69700073B101928**
-114S-xxxx-129700074B101929**
-114S-xxxx-189700075B101930**
-114S-xxxx-249700076B101931**

** Without transformer, the required power must be specified.
Other versions on request.

Descargas para VIT-A

NombreTipoTamañoIdiomaSello de tiempoD-/B-Número
VIT-A Datos técnicos 496.2 KB DE2023/08/2525.08.2023D00195
IT Panels Gama de productos 1.0 MB EN2019/05/1313.05.2019
Quadri di isolamento e distribuzione per sistemi IT-M in locali medici di gruppo 2 conformi alla nuova CEI 64-8;V2:2015-08 Gama de productos 1.3 MB IT2019/05/1313.05.2019
Produktübersicht IT-System Verteiler Gama de productos 850.3 KB DE2019/05/1313.05.2019