The LCM410 is a four-channel load current monitor designed for the reliable monitoring of alternating and pulsating load currents. It enables the monitoring of load currents in the range from 6 mA to 50 A at a frequency range of 42 Hz to 20 kHz.
Thanks to its compact design, occupying just 1 unit of space (DU), the LCM410 is ideal for use in confined control cabinets. Parameterisation is carried out conveniently via the Bender Connect app using the NFC interface – quickly, securely and without the need for additional interfaces or tools.
Appropriate current transformers (e.g. from the CTAC series) must be connected to the load current inputs. Individual AC RMS thresholds for early warning and main alarm can be set for each channel. Alarms are indicated by alarm LEDs on the unit and are also available via the digital outputs and the RS-485 interface.
The device also features digital inputs and outputs, as well as an analogue output. Communication with higher-level systems takes place via RS-485 using Bender Smart Connect, Modbus RTU protocol. Device settings can be configured either via BSC/Modbus RTU or via the NFC interface using the Bender Connect app.

The LCM410 is a four-channel load current monitor designed for the reliable monitoring of alternating and pulsating load currents. It enables the monitoring of load currents in the range from 6 mA to 50 A at a frequency range of 42 Hz to 20 kHz.
Thanks to its compact design, occupying just 1 unit of space (DU), the LCM410 is ideal for use in confined control cabinets. Parameterisation is carried out conveniently via the Bender Connect app using the NFC interface – quickly, securely and without the need for additional interfaces or tools.
Appropriate current transformers (e.g. from the CTAC series) must be connected to the load current inputs. Individual AC RMS thresholds for early warning and main alarm can be set for each channel. Alarms are indicated by alarm LEDs on the unit and are also available via the digital outputs and the RS-485 interface.
The device also features digital inputs and outputs, as well as an analogue output. Communication with higher-level systems takes place via RS-485 using Bender Smart Connect, Modbus RTU protocol. Device settings can be configured either via BSC/Modbus RTU or via the NFC interface using the Bender Connect app.
Special features
Load current measurement
Threshold monitoring
Display and operation
Interfaces
Supply voltage
| Type | Display | I/Os, relays (changeover) | Supply voltage | Design | Art. No. |
|---|---|---|---|---|---|
| LCM410 | LED bar graph | M+, Q, I | 24 V DC | 1 DU | B85604049 |
Power supply
| Type | max. connected current transformers | Art. No. |
|---|---|---|
| STEP-PS/1 AC/24 DC/0.5 | 4 | B94053110 |
| STEP-PS/1 AC/24 DC/1.75 | 14 | B94053111 |
| STEP-PS/1 AC/24 DC/4.2 | 34 | B94053112 |
Measuring current transformers
| Type |
|---|
| CTAS series |
| CTAC series |
| W… series |
| WR… series |
| WS… series |
| Name | Category | Size | Language | Timestamp | D-/B-Number |
|---|---|---|---|---|---|
| UKCA - LCM410 | Declarations of Conformity | 169.0 KB | 2026/11/0202.11.2026 | ||
| LCM410 | Datasheets | 1.2 MB | DE | 2026/06/2323.06.2026 | D00546 |
| LCM410 | Datasheets | 1.2 MB | EN | 2026/06/2323.06.2026 | D00546 |
| LCM410 | Manuals | 4.0 MB | DE | 2026/06/1010.06.2026 | D00546 |
| LCM410 | Manuals | 3.9 MB | EN | 2026/06/1010.06.2026 | D00546 |
| LCM410 | Quickstarts | 1.3 MB | DE | 2026/06/1111.06.2026 | D00546 |
| LCM410 | Quickstarts | 1.3 MB | EN | 2026/06/1111.06.2026 | D00546 |
| LCM410 | CE Declarations of Conformity | 168.3 KB | 2026/10/2626.10.2026 |