A combined heat and power unit (CHP) is a modular system for the extraction of electrical energy and heat. This is operated at the point of heat consumption. It is based on the principle of combined heat and power. Combustion engines, e.g. diesel, vegetable oil or gas engines, gas turbines and Stirling engines can all be used as drive for the power generator. As with generators, the electrotechnical monitoring is based on the insulation level or on the existing fault current, depending on the supply system (IT, TN). The frequency and the voltage also need to be within a specific range in order to be able to be fed into the general power grid.
Name | Category | Size | Language | Timestamp | D-/B-Number |
---|---|---|---|---|---|
Product Overview ISOMETER®/ISOSCAN® | Product Overviews | 5.3 MB | EN | 2024/02/1616.02.2024 | |
Product Overview - Residual Current Monitoring | Product Overviews | 6.3 MB | EN | 2024/10/2929.10.2024 | |
Safe Connection to the Grid VMD460-NA | Flyers | 222.0 KB | EN | 2019/05/1313.05.2019 | D00001 |
Renewable energies: Photovoltaics | Market Segment Brochures | 2.0 MB | EN | 2023/06/1616.06.2023 |
Products
Ground-fault monitoring device for ungrounded AC/DC control circuits
AC/DC ground-fault monitor
Network and system protection (NS protection) for monitoring the power infeed of power generation systems
Ground-fault monitoring device for ungrounded AC/DC control circuits
AC/DC ground-fault monitor
Network and system protection (NS protection) for monitoring the power infeed of power generation systems
Messrelais und Schutzeinrichtungen - Teil 127: Funktionsnorm für Über-/Unterspannungsschutz
Regola tecnica di riferimento per la connessione di Utenti attivi e passivi alle reti AT ed MT delle imprese distributrici di energia elettrica (Reference technical rules for the connection of active and passive consumers to the HV and MV electrical networks of distribution Company)
Anwendungsregel:2011-08 Erzeugungsanlagen am Niederspannungsnetz Technische Mindestanforderungen für Anschluss und Parallelbetrieb von Erzeugungsanlagen am Niederspannungsnetz
Specifieke technische aansluitingsvoorschriften voor gedecentraliseerde productie-installaties die in parallel werken met het distributienet
Selbsttätige Schaltstelle zwischen einer netzparallelen Eigenerzeugungsanlage und dem öffentlichen Niederspannungsnetz (Norm wurde zurückgezogen und durch DIN VDE V 0126-1-1 ersetzt)
Recommendations for the Connection of Generating Plant to the Distribution Systems of Licensed Distribution Network Operators
Recommendations for the Connection of Generating Plant to the Distribution Systems of Licensed Distribution Network Operators
Recommendations for the Connection of Type Tested Small-scale Embedded Generators (up to 16A per phase) in parallel with Low Voltage Distribution Systems
Recommendations for the Connection of Type Tested Small-scale Embedded Generators (up to 16A per phase) in parallel with Low Voltage Distribution Systems